The operation check of the toner supply motor and/or toner bottle drive motor is performed by a forced toner supply, not OUTPUT Check.

  • The operation check of the toner supply motor and/or toner bottle drive motor is performed by a forced toner supply, not OUTPUT Check.

  1. Do [Force Tnr Supply: Exe (SP3-050-003 to 006)] for the applicable color twice. If there is enough toner in the toner supply unit, the toner bottle drive motor will not work.

    SP No.

    SP Name

    SP3-050-003

    Force Tnr Supply: Exe Execute: K

    SP3-050-004

    Force Tnr Supply: Exe Execute: C

    SP3-050-005

    Force Tnr Supply: Exe Execute: M

    SP3-050-006

    Force Tnr Supply: Exe Execute: Y

  2. Do [Manual ProCon :Exe Density Adjustment (SP3-011-002)] once.

  • If the operation of the toner bottle drive motor could not be checked, do step1 again after the manual execution of density adjustment.