The Toner Supply Type can be selected with SP3-400-001 to 004 (Toner Supply Type: Select).

0:FIXED

2:PID

4:DANC

  • 0: Fixed (Fixed supply method)
    The toner supply time is calculated based on the supply rate of SP3-440-001 to 004 (Fixed Supply Mode: Fixed Rate).

  • 2: PID (Proportion Integral Differential)
    The amount of toner supply is calculated based on the pixel information and TD sensor information.

  • 4: DANC (Divided Active Noise Control) (Default)
    Conventional PID method + active noise control. It controls the timing to supply the developer to minimize uneven developer density in the development unit.