The Toner Supply Type can be selected with SP3-400-001 to 004 (Toner Supply Type: Select).
0:FIXED
2:PID
4:DANC
- 0: Fixed (Fixed supply method)
The toner supply time is calculated based on the supply rate of SP3-440-001 to 004 (Fixed Supply Mode: Fixed Rate). - 2: PID (Proportion Integral Differential)
The amount of toner supply is calculated based on the pixel information and TD sensor information. - 4: DANC (Divided Active Noise Control) (Default)