SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC441-00 | D | Drum transfer motor: Lock |
Motor status is observed at 100ms intervals during motor ON, and the unlock status is detected at least 20 times. | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC442-00 | D | ITB Lift Error |
Even though the ITB contact and release motor (toner bottle drive motor (M) (M13) rotates, the ITB contact and release sensor (S32) failed to detect the specified sensor feeler status within specified time.
Signal detection sampling period: 10msec | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC452-00 | D | Paper transfer contact and release motor error |
Even though the paper transfer contact and release motor (M18) rotates, the ITB contact and release sensor (S32) failed to detect the specified sensor feeler status within specified time.
Signal detection sampling period: 10msec | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC491-00 | D | High voltage power source: charge/development: output error |
SC detection signal (charge/development) is L (abnormal) for 200 ms consecutively during high voltage (charge/development) output. | ||
H/W error
Load error
| ||
Check if the SC occurs by turning the power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC492-00 | C | High voltage power source: image transfer/paper transfer: output error |
SC detection signal (transfer) is L (abnormal) for 200 ms consecutively during high voltage (transfer) output. | ||
H/W error
Load error
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC497-00 | C | Machine temperature detection thermistor error |
Temperature sensor output error: Below 0.56V, or above 3.0V | ||
| ||
Check if the SC occurs by turning the power OFF then ON. If the SC occurs again, do the following steps. Check if the SC reoccurs by cycling the power after each step.
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC498-00 | C | Temperature and humidity sensor error |
Temperature sensor output error: Below 0.76V, or above 2.90V, or Moisture sensor output error: more than 2.4V | ||
| ||