IM C6000/C5500/C4500
Name | Output connector | Capacity | Part number | Market exchange possible |
---|---|---|---|---|
Voltage | Part name | Remarks | ||
FU101 | CN985 (Fusing center heater) CN986 (Fusing edge heater) | 15A(NA) 8A | 11071241 (NA) 11071366 | Yes |
AC | TLC-15A-N4 (NA) FIH 250V 8A(EM)8A | Installed on AC controller board | ||
FU102 | CN988 (DC power supply) | 15A (NA) 8A | 11071241(NA) 11071366 | Yes |
AC | TLC-15A-N4 (NA) FIH 250V 8A(EM)8A | Installed on AC controller board | ||
FU110 | CN921(Heater for Tray1, 2, and optional trays) CN922 (Heater for Scanner and PCU) | 2A | 11071225 | NO |
AC | SLT 250V 2A | Installed on Heater Board (Service Part) | ||
FU105 | None | 2A | 11071362 | NO |
AC | SCT2A | Installed on AC controller board | ||
FU1 | CN911(IOB) | 5A | 11071351 | NO |
5V | SCT5A | Installed on DC power supply | ||
FU2 | CN911(IPU) | 5A | 11071351 | NO |
5V | SCT5A | Installed on DC power supply | ||
FU3 | CN912(IOB) | 10A | 11071283 | NO |
24V | FBT 250V 8A(EM) | Installed on DC power supply | ||
FU4 | CN917 (Interlock switch [IOB]) | 10A | 11071283 | NO |
24V | FBT 250V 8A(EM) | Installed on DC power supply | ||
FU5 | CN917 (Interlock switch [IOB]) | 10A | 11071283 | NO |
24V | FBT 250V 8A(EM) | Installed on DC power supply | ||
FU7 | CN913(FIN) CN914(BANK) | 10A | 11071283 | NO |
24V | FBT 250V 8A(EM) | Installed on DC power supply |
IM C3500/C3000/C2500/C2000
Name | Output connector | Capacity | Part number | Market exchange possible |
---|---|---|---|---|
Voltage | Part name | Remarks | ||
FU101 | CN985 (Fusing center heater) CN986 (Fusing edge heater) | 15A (NA) 8A | 11071241(NA) 11071366 | Yes |
AC | TLC-15A-N4 (NA) FIH 250V 8A(EM)8A | Installed on AC controller board | ||
FU102 | CN988 (DC power supply) | 15A(NA) | 11071241(NA) 11071366 | Yes |
AC | TLC-15A-N4 (NA) FIH 250V 8A(EM)8A | Installed on AC controller board | ||
FU110 | CN921(Heater for Tray1, 2, and optional trays) CN922 (Heater for Scanner and PCU) | 2A | 11071225 | NO |
AC | SLT 250V 2A | Installed on Heater Board (Service Part) | ||
FU105 | None | 2A | 11071362 | NO |
AC | SCT2A | Installed on AC controller board | ||
FU1 | CN911(IOB) | 5A | 11071229 | NO |
5V | SLT 250V 5A | Installed on DC power supply | ||
FU2 | CN911(IPU) | 5A | 11071229 | NO |
5V | SLT 250V 5A | Installed on DC power supply | ||
FU3 | CN912(IOB) | 8A | NO | |
24V | 51MS(P)080L | Installed on DC power supply | ||
FU4 | CN917 (Interlock switch [IOB]) | 8A | NO | |
24V | 51MS(P)080L | Installed on DC power supply | ||
FU5 | CN917 (Interlock switch [IOB]) | 8A | NO | |
24V | 51MS(P)080L | Installed on DC power supply | ||
FU7 | CN913(FIN) CN914(BANK) | 8A | NO | |
24V | 51MS(P)080L | Installed on DC power supply |