Lookup Table
Item
MP C2004/C2504/C3004/C3504/C4504/C5504/C6004
(Previous Model)
IM C2000/C2500/C3000/C3500/C4500/C5500/C6000
Board CompositionIPU, BCUIPU and BCU combined into a BICU
NVRAM2 (2M×2)1 (4M×1)
Java VMStandard onboard functionSupplied as an optional SD card
Anti-Condensation HeaterNot provided with the calendar function

Provided with the calendar function (in units of months)

Proximity Sensor (S49)

SC869-01

Occurrence Condition

If continuously switched on for 24 hours

If continuously switched on for 480 hours

Proximity Sensor (S49)

SC869-02

Occurrence Condition
On detecting user operation 20 times when switched offOn detecting user operation 300 times when switched off

Operation Panel Harness

Between operation panel and IPUBetween  operation pane and CTL
Operation Panel VersionG2G2.5
Changes
  • Interface Slot
    On the previous model, the USB port [A] was used for connecting the USB cable [B] supplied with USB Device Server Option Type M19. For the USB connection, the service technician removed the resin cover with nippers.

    On this model, the machine is shipped with the USB port exposed so that the customer can use it immediately.

    The board of the Device Server Option has been changed (from type M19 to type M37) and is not equipped with a USB port [A].

 

  • Optional PCB Slot (2 slots reduced to 1)
    The previous model (Met-C2cde) was equipped with two optional PCB slots, but the present model has only one.

    It is not possible to attach two options (because it requires two Rios slots).