Lookup Table
Item | MP C2004/C2504/C3004/C3504/C4504/C5504/C6004 (Previous Model) | IM C2000/C2500/C3000/C3500/C4500/C5500/C6000 |
---|---|---|
Tools for Attachment | Screws | Lock lever (same as Met-P2) |
Changes
- Tools for Attachment
The tools for attaching and removing the fusing unit are the same as those for the user maintenance model Met-P2 (using lock lever, not screws). Parts on Main Unit
A cover [A] to protect the shield drive motor (M28) has been added to the main unit.
Models (abyz) without the shield drive motor (M28) are equipped with a cover to protect the harness.
- Notes about Resetting the Counter
On this model, the fusing unit (400 K) and dust filter (400 K) are intended to be replaced at the same time.
Thus, when the fusing unit is replaced, the dust filter’s counter is reset.
Item with Counters that are Reset when the Fusing Unit is Replaced
Previous model: fusing unit, fusing sleeve belt, pressure roller
Present model: fusing unit, fusing sleeve belt, pressure roller, dust filter