Lookup Table
Item
MP C2004/C2504/C3004/C3504/C4504/C5504/C6004
(Previous Model)
IM C2000/C2500/C3000/C3500/C4500/C5500/C6000

Tools for Attachment

ScrewsLock lever (same as Met-P2)
Changes
  • Tools for Attachment
    The tools for attaching and removing the fusing unit are the same as those for the user maintenance model Met-P2 (using lock lever, not screws).

  • Parts on Main Unit

    A cover [A] to protect the shield drive motor (M28) has been added to the main unit.

    Models (abyz) without the shield drive motor (M28) are equipped with a cover to protect the harness.

  • Notes about Resetting the Counter

    On this model, the fusing unit (400 K) and dust filter (400 K) are intended to be replaced at the same time.

    Thus, when the fusing unit is replaced, the dust filter’s counter is reset.

    Item with Counters that are Reset when the Fusing Unit is Replaced

    • Previous model: fusing unit, fusing sleeve belt, pressure roller

    • Present model: fusing unit, fusing sleeve belt, pressure roller, dust filter