Connection schematic diagram
Orange: Relay harness
Yellow: Distribution harness
Green: Ground wire
- Remove the rear cover of 2tray PFU.
- Attach the supplied clamps.
Left: large clamp, Right: small camp - Remove the cable cover [A].
- Install the supplied entrance bracket [A].
Use the supplied M3x6 screw, and the screw removed in Step 2 of the previous section "Installing the Heater to LCIT RT3040". - Fix the relay harness [A] to the entrance bracket.
- Route the relay harness [A] and then clamp the unshielded part of the connector base [B].
- Fix the ground wire.
- Connect the distribution harness to:
1. Relay harness (to orange)
2. 2 tray PFU heater harness (to blue)
Clamp the distribution harness at the position between the bind parts [A]. - Connect the long harness to the relay connector on the main machine.
- Reattach the rear cover.