ADF side-to-side, leading edge registration and trailing edge
Use A3/DLT paper to make a temporary test chart as shown below.
A: Leading edge registration- Put the temporary test chart on the ADF, and then make a copy from one of the feed stations.
Check the registration. Check the leading edge and side-to-side registration. Adjust the following SP modes if necessary.
Standard: 4.2 ± 2 mm for the leading edge registration, 2 ± 1 mm for the side-to-side registration. Use the following SP modes to adjust if necessary.SP Code
What It Does
Adjustment Range
SP6-006-001
Side-to-Side Regist: Front
± 3.0 mm
SP6-006-003
Leading Edge Registration
± 5.0 mm
SP6-006-005
Buckle: Duplex Front
± 3.0 mm
SP6-006-006
Buckle: Duplex Rear
± 2.5 mm
SP6-006-007
Rear Edge Erase (Trailing Edge)
± 10.0 mm
ADF sub-scan magnification
- Put the temporary test chart on the ADF, and then make a copy from one of the feed stations.
- Check the magnification ratio. Adjust with SP6-017-001 if necessary.
Specification (magnification error)
- Sub-scan without magnification: ±2.75%
- Sub-scan with magnification: ±2.75%