Symptom
Under the usage environment of this machine, at the placement location, fluorescent and/or LED lamps flicker.
Cause
As a result of the voltage drop occurs, when the fusing lamp is applied an electrical current. It depends on the electrical power environment, at the customer's placement location.
Solution
The procedure varies by the flicker occurrence timing. So check the occurrence timing, and do the procedure that matches the timing.
Occurrence Timing
Timing | Solutions | Side effect |
---|---|---|
Recovery from energy saving | Set SP1-135-001 (Inrush Control) to "1 (ON)". | Recovery time from energy saving becomes slower approx. 0.4 sec.. |
After the recovery from energy saving
| Set SP1-135-001 (Inrush Control) to "1 (ON)". Set SP1-135-002 (Flicker Control) to "1 (ON)". |
|
If it has not been improved in the above, do the following procedures in addition;
| The fusing temperature drops during the operation. After copying starts, the fusing temperature is raised up to a printable temperature. Because of that, copying completion time becomes slower (approx. 1-2 sec.). | |
Printing | Set SP1-135-002 (Flicker Control) to "1 (ON)". |
|
Related SP to Fusing Offsets
SP Name | SP No. | Value |
---|---|---|
Print Target Temp.:Plain1:FC:Center | SP1-105-001 | As initial values + 10 degrees are the upper limits, change values to improve offsets. |
Print Target Temp.:Plain1:BW:Center | SP1-105-003 | |
Print Target Temp.:Plain2:FC:Center | SP1-105-005 | |
Print Target Temp.:Plain2:BW:Center | SP1-105-007 | |
Print Target Temp.: Thin:FC:Center | SP1-105-009 | |
Print Target Temp.: Thin:BW:Center | SP1-105-011 | |
Print Target Temp.: M-thick:FC:Center | SP1-105-013 | |
Print Target Temp.: M-thick:BW:Center | SP1-105-015 |