The ‘SC Table’ section shows the SC codes for controller errors and other errors. The latter are put into four types. The type is determined by their reset procedures. The table shows the classification of the SC codes.

Type

Display

How to reset

A

The SC is immediately displayed on the operation panel when SC occurs.

The error involves the fusing unit. The machine operation is disabled. The user cannot reset the error.

  • When canceling a fusing unit SC, (SC544-00/ SC554-00/ SC564-00/ SC574-00), perform part replacement in accordance with the above procedure.

Reset the SC (set SP5-810-1) and then cycle the main power off and on.

B

When a function is selected, the SC is displayed on the operation panel.

The machine cannot be used (down-time mitigation).

Turn the operation switch off and on.

C

No display on the operation panel.

The machine operates as usual.

Only the SC history is updated.

D

The SC is displayed on the operation panel.

The machine cannot be used (machine-error SC).

Turn the main n power switch off and on.

  • When an ordinary SC (type D) is generated, an automatic reboot is performed. When an event is reported by the customer support system, even in the event of an ordinary SC, reboot is not performed. During automatic reboot, a confirmation screen is displayed after the reboot.
  • When automatic reboot occurs twice continuously, an SC is displayed without rebooting, and logging count is performed. Also, when an SMC print is output, an * mark is added alongside the SC number for clarity.
  • Automatic reboot can be enabled or disabled with SP5-875-001 (SC automatic reboot setting) (default value: ON).

SP descriptions

  • SP5-875-001 (SC automatic reboot: Reboot Setting)
    Enables or disables the automatic reboot function when an SC error occurs.
    0: The machine reboots automatically when the machine issues an SC error and logs the SC error code. If the same SC occurs again, the machine does not reboot.
    1: The machine does not reboot when an SC error occurs.
    The reboot is not executed for the pattern A or C.