SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC632-00

D

Counter device error 1

  

After 3 attempts to send a data frame to the optional counter device via the serial communication line, no ACK signal was received within 100 ms.

  

Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged.

  
  1. Turn the main power off/on.
  2. Check the serial communication line.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC633-00

D

Counter device error 2

  

After communication was established, the controller received the brake signal from the accounting device.

  

Serial line between the optional counter device, the relay board and copier control board is disconnected or damaged.

  
  1. Turn the main power off/on.
  2. Check the serial communication line.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC634-00

D

Counter device error 3

  

A backup RAM error was returned by the counter device.

  

Counter device control board or the backup battery of counter device defective

  
  1. Replace the counter device control board.
  2. Replace the backup battery.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC635-00

D

Counter device error 4

  

A backup battery error was returned by the counter device.

  

Counter device control board or the backup battery of counter device defective

  
  • Replace the counter device control board.
  • Replace the backup battery.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC636-01

D

IC Card Error (Expanded authentication module error)

  

Issued when expanded authentication management is set to "ON" but either of the following occur.

  • There is no expanded authentication module in the machine.
  • The SD card or the file of the expanded authentication module is broken.
  • There is no DESS module in the machine.
  
  • There is no DESS module in the machine (models on which the function is optional).
  • There is no expanded authentication module in the machine.
  • The SD card or the file of the expanded authentication module is broken.
  
  • Set a working SD card/expanded authentication module file.
  • Install the DESS module.
  • In the SSP mode set SP5-401-160 to "0".
  • In the SSP mode, set SP5-401-161 to "0".
  • Replace the NVRAM.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC636-02

D

IC Card Error (Version error)

  

The version of the expanded authentication module is not correct.

  

Incorrect module version

  

Install the correct file of the expanded authentication module.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC637-01

D

Tracking Information Notification Error (Tracking application error)

  

Tracking information was lost.

  
  • Tracking SDK application error
  • Internal notification error
  

Turn the main power off/on.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC637-02

D

Tracking Information Notification Error (Management server error)

  

Tracking information was lost.

  

Communication with tracking management server failed.

  • Network error
  • tracking management server error
  • Tracking SDK application error
  

Turn the main power off/on.

SC No.

Type

Details (Symptom, Possible Cause, Troubleshooting Procedures)

SC641-00

D

Communication error between BICU and Controller board.

  

Controller board does not respond after BICU tries to communicate three times.

  
  • Controller board software error
  • Connect error between BICU and Controller board
  • Engine board software error
  
  • Check connections between Controller board and BICU.
  • Turn the main switch off and on.

SC No.

Type

Details (Symptom, Possible Cause, Troubleshooting Procedures)

SC641-01

D

Communication error between BICU and Controller board (Timeout)

SC641-02D

Communication error between BICU and Controller board (Timeout)

SC641-03DCommunication error between BICU and Controller board (Timeout)
SC641-04DCommunication error between BICU and Controller board (Timeout)
  Perform the same troubleshooting as for SC641-00.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC650-01

C

Remote Service Modem Communication Error (Dialup authentication failure)

  
  • An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected at power on.
  • Displayed only when an error is detected while RC Gate is operating.
  • SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP).
  

Dialup authentication failure

  

Check the following SPs.

  • SP5-816-156
  • SP5-816-157

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC650-04

C

Remote Service Modem Communication Error (dialup failing because of incorrect modem configuration)

  
  • An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected at power on.
  • Displayed only when an error is detected while RC Gate is operating.
  • SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP).
  

Dialup failing because of incorrect modem configuration

  

Check if the setting of SP5-816-160 is correct.

If it is correct, then there is a software bug.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC650-05

C

Remote Service Modem Communication Error (insufficient current or connection error)

  
  • An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected at power on.
  • Displayed only when an error is detected while RC Gate is operating.
  • SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP).
  

Insufficient current or connection error

  

The line is not supported and nothing can be done.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC650-13

C

Remote Service Modem Communication Error (RC Gate Type M was installed but modem is not present (detected during operation))

  
  • An error related to communication (dialup connection, modem board etc.) using the RC Gate Type M was detected or an error that prevents RC Gate operation was detected at power on.
  • Displayed only when an error is detected while RC Gate is operating.
  • SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP).
  

RC Gate Type M was installed but modem is not present (detected during operation)

  
  • If a modem board is not installed, install it.
  • Check again if the modem driver configurations (SP5-816-160, SP5-816-165 to 171) are correct.
  • If the problem is not solved, replace the modem.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC650-14

C

Remote Service Modem Communication Error (RC Gate Type N was installed but modem is present or wired/wireless LAN is not working correctly)

  
  • An error related to communication (dialup connection, modem board etc.) using the RC Gate was detected or an error that prevents RC Gate operation was detected at power on.
  • Displayed only when an error is detected while RC Gate is operating.
  • SC is not issued if an error occurs during RC Gate installation (because it can be referenced using SP).
  

RC Gate Type N was installed but modem is present or wired/wireless LAN is not working correctly

  
  • If a modem board is attached, remove it.
  • Check if wired/wireless LAN works.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC651-01

C

Illegal Remote Service Dial-up (Chat program parameter error)

  

An unexpected error occurred when RC Gate Type M dialed up the NRS Center.

  

Software bug

  

Logging only.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC651-02

C

Illegal Remote Service Dial-up (Chat program execution error)

  

An unexpected error occurred when RC Gate dialed up the NRS Center.

  

Software bug

  

Logging only.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC652-00

A

Remote service ID2 mismatching

  

There was an authentication mismatch between ID2 for @Remote, the controller board, and NVRAM.

  
  • Used controller board installed
  • Used NVRAM installed (such action is not allowed.)
  
  • If this occurs during RC Gate installation:
    Check the validity of the certificate and the NVRAM, check the machine serial number, write the common certificate, and then begin installation again.
  • If this occurs after RC Gate installation:
    Clear the RC Gate install status, check the validity of the certificate and the NVRAM, check the machine serial number, write the common certificate, and then begin installation again.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC653-00

A

Incorrect remote service ID2

  

ID2 stored in the NVRAM has either of the following problems.

  • Number of characters is not 17.
  • Includes a character that cannot be printed.
  • All spaces
  • NULL
  

Replace the NVRAM.

  

Clear the RC Gate install status, write the common certificate, and then begin installation again.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC670-01

D

Engine start up error when the machine boots up

  
  • /ENGRDY signal was not asserted when the machine was turned on.
  • PCI I/F is not linked up when the machine returns from energy saving mode.
  • EC/PC/SC response was not received within specified time from power on.
  • Writing to Rapi driver failed (the other party not found through PCI).
  • BICU is down / unstable
  

Engine board does not start up.

  

Refer to When SC670 (Engine start up error) is displayed

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC670-02

D

Engine start up error when the machine is in operation

  
  • CPU reset by software
  • CPU reset by anomaly CPU
  • CPU reset by hardware defect / noise
  • Hardware defect
  

Engine board reset unexpectedly.

  

Refer to When SC670 (Engine start up error) is displayed

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC670-03

D

IPU start up error when the machine boots up

VDET_EPCI signal was not asserted when the machine was turned on.

  • BICU, PSU, and/or CTL defective
  • Incorrect connection between CTL and BICU.
  • Harness of BICU disconnected

Refer to When SC670 (Engine start up error) is displayed

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC670-04

D

Communication error between the engine and controller

Communication could not linked up.

  • BICU and/or CTL defective
  • Incorrect connection between CTL and BICU.

Refer to When SC670 (Engine start up error) is displayed

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC670-05

C

Link up error

Communication could not linked up.

  • CTL board defective
  • BICU defective
  • Incorrect connection between CTL and BICU.

Logging only.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-00

D

Controller start up error

  

After the machine was powered on, communication between the controller and the operation panel was not established.

  
  • Controller stalled
  • Board installed incorrectly
  • Controller board defective
  • Operation panel connector loose, broken, or defective
  • Controller late
  

Refer to When SC672 (Controller start up error) is displayed.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-10

D

Controller start up error

  

After the machine was powered on, communication between the controller and the operation panel was not established.

  
  • Assembly fault (controller board, memory (DIMM), operation panel harness connection)
  •  Parts defective (controller board, memory (DIMM), operation panel harness, operation panel, BICU)
      
  • Controller stall due to software trouble
  

Refer to When SC672 (Controller start up error) is displayed.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-11

D

Controller start up error

  

After the machine was powered on, communication between the controller and the operation panel was not established, or communication with controller was interrupted after a normal startup.

  
  • Assembly fault (controller board, memory (DIMM), operation panel harness connection)
  • Parts defective (controller board, memory (DIMM), operation panel harness, operation panel, BICU)
     
  • Controller stall due to software trouble
  

Refer to When SC672 (Controller start up error) is displayed.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-12

D

Controller start up error

  

Communication with controller was interrupted after a normal startup.

  
  • Assembly fault (controller board, memory (DIMM), operation panel harness connection)
  • Parts defective (controller board, memory (DIMM), operation panel harness, operation panel, BICU)
     
  • Controller stall due to software trouble
  

Refer to When SC672 (Controller start up error) is displayed.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-13

D

Controller start up error

  

The operation panel detects that the controller is down due to other reason shown in SC672-10, SC672-11, and SC672-12.

  
  • Assembly fault (controller board, memory (DIMM), operation panel harness connection)
  • Parts defective (controller board, memory (DIMM), operation panel harness, operation panel, BICU)
     
  • Controller stall due to software trouble
  

Refer to When SC672 (Controller start up error) is displayed.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC672-20

D

Controller start up error

SC672-21DController start up error
  

SC672-20: USB cable defective

SC672-21: Controller board defective

  -
  

Refer to When SC672 (Controller start up error) is displayed.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC673-01

D

System application communication error (Smart operation panel)
  

The system application (Monitor Service) of Smart Operation Panel performed abnormal operation.

  -
  

Turn the main switch off and on.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC673-10

D

Operation panel Flair communication error (Smart Operation Panel)

  

This SC is issued only for the machine that has the Smart Operation Panel installed.

  • Communication between Smart Operation Panel and main machine (this is called "Flair communication") is not sent to Smart Operation Panel.
  • SP setting (SP5-748-201) for Smart Operation Panel is not activated.
  

The CATS module (controller) did not see the response to notification of monitoring service module (operation panel).

  
  1. Turn the main power OFF/ON.
  2. Set SP5-748-201 (OpePanel Setting: Cheetah Panel Connect Setting) to "1: Connect" if the value is "0: Not connect".
 SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC674-01

D

Transfer Error (M2P error)

  

The video transfer error has occurred on the controller board.

If image data transfer to the engine fails for some reason, an SC occurs.

  

Controller Board/software defective

  

Turn the main power OFF/ON.

SC674-02DTransfer Error (PCI error)
  

The expanded engine ASIC has failed in its attempt to access another PCI device.

The PCI error may occur simultaneously with the M2P error (SC674-01).

  Controller Board/software defective
  Turn the main power OFF/ON.