- When installing this option, turn OFF the main power and unplug the power cord from the wall socket. If installing without turning OFF the main power, an electric shock or a malfunction may occur.
- The bridge unit cannot be used together with the following peripherals:
- Internal Shift Tray SH3080 (D3FV)
- Side Tray Type M37 (D3FX)
- Internal Finisher SR 3250 (D3FG)
- Internal Finisher SR 3300 (D3FT)
- Internal Multi-Fold Unit FD3010 (D3FS) - To use together with the "1 Bin Tray BN3130", attach the "1 Bin Tray BN3130" first before installing the bridge unit.
Remove the packing tapes and retainers, and remove the accessories (screws, etc.).
- Remove the interval tray [A].
- Remove the paper exit tray [A].
- Remove the connector cover [A].
- Remove the paper exit feeler [A].
- Tuck in the lever [A] for detecting when the tray is full.
- Remove the driven roller [B] at the machine’s exit tray and attach the supplied driven roller [A].
- Insert a flathead screwdriver into the depression in the center, and then, lifting the driven roller, unlock the part indicated by the red arrow.
- When attaching the driven roller, push its center all the way in until it clicks.
[A]: The supplied driven roller has flat rollers.
[B]: The machine’s standard driven roller has drum-type rollers (as indicated by red frames).The spring arm on the flat roller might be disconnected due to the vibration or shock. After attaching the roller, perform a visual check whether the state of assembly is normal or not.
[A]: Normal position, [B]: spring arm is disconnected.
- Attach the paper support guide [A] (Tab x4 ).
- Open the front cover.
Remove the upper left cover [A].
- The screw removed is used again in step 16.
- Remove the proximity sensor left cover [A].
- Attach the bracket [A].
- Reattach the proximity sensor left cover [A].
- Attach the bridge unit [A] to the machine.
- Reattach the inverter tray.
- Attach the supplied upper left cover [A].
Use the screw removed in step 10. - Attach the L type connecting bracket [A].
To fix the bridge unit securely on the machine, tighten the finisher's joint bracket and L type connecting bracket [A] together when installing the finisher. - Complete the bridge unit attachment.
Refer to the procedure for connecting the optional unit downstream of the bridge unit.- Booklet Finisher SR3240 (D3BB) (Booklet Finisher SR3290 (D3FN) / Finisher SR3280 (D3G4))
- Finisher SR3230 (D3BA) (Booklet Finisher SR3290 (D3FN) / Finisher SR3280 (D3G4))
- Booklet Finisher SR3220 (D3B9) (Booklet Finisher SR3270 (D3FQ))
- Finisher SR3210 (D3B8) (Finisher SR3260 (D3FR))