• Do not touch the rollers but hold the upper/lower resin part [A] when you lift the Image Transfer Unit. Touching the rollers may cause poor image quality.

  1. Remove the Image transfer belt unit. (Image Transfer Belt Unit)
  2. Remove the image transfer front cover. (Image Transfer Cleaning Unit
  3. Remove the image transfer upper cover [A].
  4. Remove the bracket [A].
  5. Remove the brackets [A] [B].
  6. Remove the image transfer cleaning unit. (Image Transfer Cleaning Unit)
  7. Remove the tension fixing frames [A] and [B] (front side: black, rear side: gray).
  8. Holding the resin parts on the top and bottom, position the image transfer unit with the front side underneath.
  9. Rotate the gear [A] to change to the OPEN position.
    The part in the red circle opens.
  10. Release the tension, and remove the belt.