SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC900-00 | A | Electric counter error |
The electric total counter value is out of specification. Error is detected when increasing the total counter. | ||
| ||
Replace the NV-RAM. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC910-00 | B | External controller error 1 |
- | ||
- | ||
Turn the main power OFF/ON. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC910-01 | C | External controller error 1 |
SC910-02 | C | External controller error 2 |
SC910-03 | C | External controller error 3 |
-01 The external controller receives the unexpected command from the engine side. -02 The external controller wrongly receives the command from the engine side. -03 The external controller receives the engine status out of specification. | ||
Refer to the instructions for the external controller | ||
Turn the main power OFF/ON. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC910-10 | C | External controller error 10 |
The external controller error is detected due to other reason shown in SC910-01 to -03. | ||
Refer to the instructions for the external controller | ||
Turn the main power OFF/ON. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-00 | B | External controller error 2 |
The external controller alerted the machine about an error. | ||
Refer to the instructions for the external controller | ||
Turn the main power off/on. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-06 | B | Ethernet TCP/IP: Invalid configuration during enable |
Configuration error involved in the communication with the IPDS host system (only occurs when IPDS is installed on the external controller) | ||
If rebooting the external controller does not solve the problem, replace the motherboard of the external controller. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-10 | B | Internal printing: File system error |
File system error of the internal print (such as file corruption) | ||
If rebooting the external controller does not solve the problem, re-install the system software of the external controller. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-11 | B | Unexpected network condition |
| ||
If rebooting the external controller does not solve the problem, re-install the system software of the external controller. Then if the problem is not solved, replace the motherboard of the external controller. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-20 | B | Program check - Type 1 |
SC911-21 | B | Program check - Type 2 |
SC911-22 | B | Program check - Type 3 |
Programming error | ||
Reboot the external controller. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-24 | B | CPU0 Temperature Alert |
CPU0 temperature error by H/W checking
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-26 | B | CPU1 Temperature Alert |
CPU1 temperature error by H/W checking
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-42 | B | Memory configuration has changed. |
This error occasionally occurs at the initial startup after the software installation of the external controller because of a memory shortage. | ||
If rebooting the external controller does not solve the problem, replace the DIMM or the motherboard of the external controller. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-43 | B | Invalid features defined |
Invalid features defined | ||
Reboot the external controller. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-44 | B | Recommended amount of memory not found |
DIMM defective | ||
If rebooting the external controller does not solve the problem, replace the DIMM or the motherboard of the external controller. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-45 | B | Recommended number of processors not found |
CPU or motherboard of external controller defective | ||
If rebooting the external controller does not solve the problem, replace the CPU/ CPU cooling fan or motherboard of the external controller. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-46 | D | File read error, hard disk |
System files corruption | ||
If rebooting the external controller does not solve the problem, do the following.
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-47 | B | File write error, hard disk |
System files corruption | ||
If rebooting the external controller does not solve the problem, do the following.
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-48 | B | Checksum error on configuration file. |
System files corruption | ||
If rebooting the external controller does not solve the problem, re-install the system software of external controller. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-49 | B | Hard disk backup to USB storage device failure |
Abnormal termination due to incomplete backup to the USB memory of external controller. | ||
If rebooting the external controller does not solve the problem, replace the USB memory of the external controller for backup. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-50 | B | Software update failed |
Abnormal termination due to the system software update file failure of external controller | ||
If rebooting the external controller does not solve the problem, re-install the update file of the external controller. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-51 | B | RDTU H/W error |
| ||
If rebooting the external controller does not solve the problem, replace the RDTU board of the external controller. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-55 | B | VM option H/W error |
Error (defective, harness disconnected or bad connection, or non-response) relating to the VM option (HDD, controller board, graphic board). | ||
If rebooting the external controller does not solve the problem, replace the HDD, controller board, graphic board for the VM option. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-56 | D | Xen VM S/W error |
Xen VM is not started normally or does not work normally. | ||
If rebooting the external controller does not solve the problem, re-install the system software of the external controller. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-57 | B | License key H/W error |
| ||
| ||
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-58 | B | License error |
| ||
If rebooting the external controller does not solve the problem, replace the USB dongle of the external controller. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-60 | B | Brand mismatch |
An invalid USB dongle is inserted. | ||
If rebooting the external controller does not solve the problem, re-install the system file of the external controller. Then if the problem is not solved, replace the USB dongle. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-61 | B | Command timeout communicating with the printer |
No response of command level from the machine to the external controller. | ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-62 | B | Print Engine communication error |
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-63 | B | A file system access error occurred in the ASCII temporary disk cache. |
System files corruption | ||
If rebooting the external controller does not solve the problem, re-install the system software of the external controller. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-64 | B | Page processing timeout |
Time-out error occurs during the page processing for print job. | ||
If rebooting the external controller does not solve the problem, there may be a problem with the job. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC911-80 | - | Turn the main power off/on. |
SC911-81 | - | |
SC911-82 | - | |
SC911-83 | - | |
SC911-84 | - | |
SC911-85 | - | |
SC911-86 | - | |
SC911-87 | - | |
SC911-88 | - | |
SC911-89 | - |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC912-00 SC913-00 SC914-00 | B | External controller error 3 |
External controller error 4 | ||
External controller error 5 | ||
The external controller alerted the machine about an error. | ||
Refer to the instructions for the external controller. | ||
Turn the main power off/on. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC919-00 | D | External controller down |
While EAC (External Application Converter), the conversion module, was operating normally, the receipt of a power line interrupt signal from the FLUTE serial driver was detected, or BREAK signal from the other station was detected. | ||
| ||
Turn the main power off/on. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC920-02 | B | Printer error (WORK memory not acquired) |
When an error is detected in the application, which makes continued operation impossible. | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC920-04 | B | Printer error (Filter process not started) |
When an error is detected in the application, which makes continued operation impossible. | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC921-00 | B | Printer error (Resident font not found) |
Resident font was not found at printer startup | ||
Preinstalled font files not found. | ||
Turn the main power off/on. |
SC NO. | Typel | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC925-00 SC925-01 | B | NetFile function error |
The NetFile file management on the HDD cannot be used, or a NetFile management file is corrupted and operation cannot continue. | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC990-00 | D | Software operation error |
Software attempted an unexpected operation. | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC991-00 | C | Recoverable software operation error |
Software attempted an unexpected operation. SC991 covers recoverable errors as opposed toCS990. | ||
| ||
Logging only |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC992-00 | D | Undefined SC issued. |
An SC, that is not controlled by the system, occurred. | ||
| ||
Turn the main power OFF/ON. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC994-00 | C | Operation error caused by abnormalities that are normally undetectable. |
An error occurred because the number of records exceeded the limit for images managed in the service layer of the firmware. | ||
This can occur if there are too many application screens open on the operation panel. | ||
Logging only. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC997-00 | D | Application function selection error |
The application selected by the operation panel key operated abnormally (No response, abnormal ending). | ||
Software bug (mainly the application) | ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
---|---|---|
SC998-00 | D | Application start error |
| ||
| ||
|