SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC900-00

A

Electric counter error

The electric total counter value is out of specification.

Error is detected when increasing the total counter.

  • Unexpected NV-RAM is attached.
  • NV-RAM defective
  • NV-RAM data corrupted.
  • Data written to unexpected area because of external factor etc.
  • The count requested by the SRM on receiving PRT is not completed.

Replace the NV-RAM.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC910-00

B

External controller error 1

-

-

Turn the main power OFF/ON.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC910-01

C

External controller error 1

SC910-02

C

External controller error 2

SC910-03

C

External controller error 3

  

-01

The external controller receives the unexpected command from the engine side.

-02

The external controller wrongly receives the command from the engine side.

-03

The external controller receives the engine status out of specification.

  

Refer to the instructions for the external controller

  

Turn the main power OFF/ON.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC910-10

C

External controller error 10

  

The external controller error is detected due to other reason shown in SC910-01 to -03.

  

Refer to the instructions for the external controller

  

Turn the main power OFF/ON.

SC No.TypeError Name/Error Condition/Major Cause/Solution
SC911-00


B


External controller error 2
The external controller alerted the machine about an error.
Refer to the instructions for the external controller
Turn the main power off/on.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-06

BEthernet TCP/IP: Invalid configuration during enable
Configuration error involved in the communication with the IPDS host system (only occurs when IPDS is installed on the external controller)
If rebooting the external controller does not solve the problem, replace the motherboard of the external controller.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-10

BInternal printing: File system error
File system error of the internal print (such as file corruption)
If rebooting the external controller does not solve the problem, re-install the system software of the external controller.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-11

BUnexpected network condition
  • Unexpected errors for the network environment
  • Motherboard of the external controller is defective
  • Configuration file or device driver corruption
If rebooting the external controller does not solve the problem, re-install the system software of the external controller. Then if the problem is not solved, replace the motherboard of the external controller.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-20BProgram check - Type 1
SC911-21BProgram check - Type 2
SC911-22BProgram check - Type 3
  Programming error
Reboot the external controller.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-24

BCPU0 Temperature Alert

CPU0 temperature error by H/W checking

  • CPU or CPU cooling fan of the external controller is defective
  • Connection error between the CPU and CPU cooling fan of the external controller
  • Exhaust heat port of the external controller is blocked
  • Check the connection between the CPU and CPU cooling fan of the external controller.
  • Check the exhaust heat port of the external controller and clean it up.
  • Replace the CPU and CPU cooling fan of the external controller.
  • Replace the motherboard of external the controller.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-26

BCPU1 Temperature Alert

CPU1 temperature error by H/W checking

  • CPU or CPU cooling fan of external controller is defective
  • Connection error between the CPU and CPU cooling fan of the external controller
  • Exhaust heat port of external controller is blocked
  • Check the connection between the CPU and CPU cooling fan of the external controller.
  • Check the exhaust heat port of the external controller and clean it up.
  • Replace the CPU and CPU cooling fan of the external controller.
  • Replace the motherboard of the external controller.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-42

 BMemory configuration has changed.
This error occasionally occurs at the initial startup after the software installation of the external controller because of a memory shortage.
If rebooting the external controller does not solve the problem, replace the DIMM or the motherboard of the external controller.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-43

BInvalid features defined
Invalid features defined
Reboot the external controller.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-44

BRecommended amount of memory not found
DIMM defective
If rebooting the external controller does not solve the problem, replace the DIMM or the motherboard of the external controller.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-45

BRecommended number of processors not found
CPU or motherboard of external controller defective
If rebooting the external controller does not solve the problem, replace the CPU/ CPU cooling fan or motherboard of the external controller.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-46

DFile read error, hard disk
System files corruption

If rebooting the external controller does not solve the problem, do the following.

  1. Re-install the system software of the external controller.
  2. Replace the HDD of the external controller.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-47

BFile write error, hard disk
System files corruption

If rebooting the external controller does not solve the problem, do the following.

  1. Re-install the system software of the external controller.
  2. Replace the HDD of the external controller.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-48

BChecksum error on configuration file.
System files corruption
If rebooting the external controller does not solve the problem, re-install the system software of external controller.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-49

BHard disk backup to USB storage device failure
Abnormal termination due to incomplete backup to the USB memory of external controller.
If rebooting the external controller does not solve the problem, replace the USB memory of the external controller for backup.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-50

BSoftware update failed
Abnormal termination due to the system software update file failure of external controller
If rebooting the external controller does not solve the problem, re-install the update file of the external controller.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-51

BRDTU H/W error
  • RDTU board of external controller is defective
  • Connection fault
If rebooting the external controller does not solve the problem, replace the RDTU board of the external controller.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-55

BVM option H/W error
Error (defective, harness disconnected or bad connection, or non-response) relating to the VM option (HDD, controller board, graphic board).
If rebooting the external controller does not solve the problem, replace the HDD, controller board, graphic board for the VM option.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-56

 DXen VM S/W error

Xen VM is not started normally or does not work normally.
There is a possibility that the system file is broken.

If rebooting the external controller does not solve the problem, re-install the system software of the external controller.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-57

BLicense key H/W error
  • USB dongle (includes the license key) of the external controller is defective
  • Connection fault
  • Reboot the external controller.
  • Re-insert the USB dongle of the external controller.
  • Replace the USB dongle of the external controller.
 

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-58

BLicense error
  • License key defective (nonconformity, file corruption and so on)
  • Unauthorized use of USB dongle for external controller (used once to another device, falsification, etc.)
If rebooting the external controller does not solve the problem, replace the USB dongle of the external controller.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-60

BBrand mismatch
An invalid USB dongle is inserted.
If rebooting the external controller does not solve the problem, re-install the system file of the external controller. Then if the problem is not solved, replace the USB dongle.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-61

BCommand timeout communicating with the printer
No response of command level from the machine to the external controller.
  • Check that the main machine is turned on.
  • Check the cable connection between external controller and main machine.
  • Restart the main machine and the external controller using the correct procedure.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-62

BPrint Engine communication error
  • Connection fault
  • Motherboard (onboard NIC) defective
  • Check that the main machine is turned on.
  • Check the cable connection between external controller and main machine.
  • Restart the main machine and the external controller using the correct procedure.
  • Replace the connection cable or motherboard of the external controller.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-63

BA file system access error occurred in the ASCII temporary disk cache.
System files corruption
If rebooting the external controller does not solve the problem, re-install the system software of the external controller.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC911-64

BPage processing timeout
Time-out error occurs during the page processing for print job.
If rebooting the external controller does not solve the problem, there may be a problem with the job.
SC No.TypeError Name/Error Condition/Major Cause/Solution
SC911-80-Turn the main power off/on.


SC911-81-
SC911-82-
SC911-83-
SC911-84-
SC911-85-
SC911-86-
SC911-87-
SC911-88-
SC911-89-

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC912-00

SC913-00

SC914-00

BExternal controller error 3
External controller error 4
External controller error 5
The external controller alerted the machine about an error.
Refer to the instructions for the external controller.
Turn the main power off/on.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC919-00

D

External controller down

While EAC (External Application Converter), the conversion module, was operating normally, the receipt of a power line interrupt signal from the FLUTE serial driver was detected, or BREAK signal from the other station was detected.

  • Controller power outage
  • Controller rebooted
  • Connection to controller loose

Turn the main power off/on.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC920-02

B

Printer error  (WORK memory not acquired)

When an error is detected in the application, which makes continued operation impossible.

  • Software bug
  • Unexpected hardware configuration (such as insufficient memory)
  • Turn the main power off/on.
  • Increase the memory storage capacity.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC920-04

B

Printer error  (Filter process not started)

When an error is detected in the application, which makes continued operation impossible.

  • Software bug
  • Unexpected hardware configuration (such as insufficient memory)
  • Turn the main power off/on.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC921-00

B

Printer error  (Resident font not found)

Resident font was not found at printer startup

Preinstalled font files not found.

Turn the main power off/on.

SC NO.

Typel

Error Name/Error Condition/Major Cause/Solution

SC925-00

SC925-01

B

NetFile function error

The NetFile file management on the HDD cannot be used, or a NetFile management file is corrupted and operation cannot continue.

  • HDD defective
  • HDD inconsistency caused by power failure during HDD access, etc.
  • Software bug
  • If another SC related to HDD errors (SC860 to SC865) is issued at the same time, the HDD is the cause. Solve the other SC.
  • If SC860 to SC865 is not issued
    1. Cycle the main power switch off/on.
  • If this does not work, initialize the HDD NetFile partition (SP5-832-011: HDD Formatting (Ridoc I/F)).
    Approval by the customer is required because documents waiting to be captured will be lost.
    The documents stored in the document box (including the documents stored in the scanner) will be retained. (It may take some time to reconstruct the management information when the HDD is accessed from the network for the first time after the initialization.)
    Procedure:
    1. In the User Tools mode, do Document Management> Batch Delete Transfer Documents.
    2. Do SP5-832-011, then turn the machine power off and on.
  • If this does not solve the problem, initialize all partitions of the HDD (SP5- 832-001: HDD Formatting (ALL)), then turn the machine power off and on.
    Approval by the customer is required because documents information in the HDD will be lost.
  • If this does not solve the problem, replace the HDD.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC990-00

D

Software operation error

Software attempted an unexpected operation.

  • Parameter error
  • Internal parameter error
  • Insufficient work memory
  • Operation error caused by abnormalities that are normally undetectable.
  • Turn the main power off/on.
  • Reinstall the software of the controller and BICU board.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC991-00

C

Recoverable software operation error

Software attempted an unexpected operation. SC991 covers recoverable errors as opposed toCS990.

  • Parameter error
  • Internal parameter error
  • Insufficient work memory
  • Operation error caused by abnormalities that are normally undetectable.

Logging only

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC992-00

D

Undefined SC issued.

An SC, that is not controlled by the system, occurred.

  • An SC for the previous model was used mistakenly, etc.
  • Basically a software bug.

Turn the main power OFF/ON.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC994-00

C

Operation error caused by abnormalities that are normally undetectable.

An error occurred because the number of records exceeded the limit for images managed in the service layer of the firmware.

This can occur if there are too many application screens open

on the operation panel.

Logging only.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC997-00

D

Application function selection error

The application selected by the operation panel key operated abnormally (No response, abnormal ending).

Software bug (mainly the application)

  • Check the optional RAM, DIMM, boards required by the application program.
  • Check if the combination of downloaded programs are correct.

SC No.

Type

Error Name/Error Condition/Major Cause/Solution

SC998-00

D

Application start error

  • No application was registered to system within a specified time after the main power was turned on.
    (No application starts/All applications have been terminated abnormally)
  • Application started but cannot be drawn now for some reason.
  • Software bug (mainly the application)
  • The optional RAM, DIMM, boards required by the application program. Are not installed correctly.
  • Turn the main power OFF/ON.
  • Check the optional RAM, DIMM, boards
  • Check the combination of programs
  • Replace the controller board.