After performing recovery on SC370, execute the following adjustment procedures.

  1. Execute SP2-111-004 (Forced Line Position: Adj. Mode d).
  2. Execute the following SPs and check the results:
    • SP2-194-007 (Execution Result)
    • SP2-194-010 (Error Result: C)
    • SP2-194-011 (Error Result: M)
    • SP2-194-012 (Error Result: Y)
      Execute result sample
      Factory default: 0
      Success: 1
  3. Execute SP3-011-001 (Manual ProCon :Exe).
  4. Execute the following SPs and check the results.
    • SP3-012-001 to 010 (Front)
    • SP3-012-011 to 020 (Center)
    • SP3-012-021 to 030 (Rear)
      Execute result sample (In order of YMCK from left)
      • Factory default:[00,00,00,00]
      • Starting adjust:[99,99,99,99]
      • Fail Vsg adjust(Y):[21,99,99,99]
      • Error of Development gamma Max(C):[99,99,55,99]
      • Succeed:[11,11,11,11]