• The fusing sleeve belt unit is designed with a highly soft material. Do not touch the fusing sleeve belt unit with your hands to prevent dents during replacement. If you have touched it and a dent has been made, the dent will gradually become larger during operation and it can cause a fusing malfunction or sleeve belt breakage.

  • To cancel SC544-02/SC554-02, it is necessary to replace the fusing unit or install an intact new unit detection fuse included with the fusing sleeve belt unit.

  • If you are replacing the fusing sleeve belt unit for PM or any reason other than canceling SC544-02/SC554-02, you can discard the fuse that is packed with the new fusing sleeve belt unit.

Adjustment before Replacing the Fusing Sleeve Belt Unit

Before replacing the fusing sleeve belt unit, set SP3-701-116 to "1" and switch the power OFF. Then replace the fusing sleeve belt unit and switch the power ON.

SP3-701 (Manual New Unit Set)

This SP is the new unit detection flag. 0: new unit detection flag OFF, 1: new unit detection flag ON

ItemSP
Fusing sleeve belt unitSP3-701-116
Replacement Procedure
  1. Remove the fusing upper cover. (Fusing Upper Cover)
  2. Remove the fusing lower cover. (Fusing Lower Cover)
  3. Remove the left frame [A].
  4. Remove the exit guide plate (left) unit [A].
  5. Remove the fusing exit driven roller [A].
  6. Remove the side plate [A].
  7. Remove the two screws.
  8. Release the boss caps on both sides, and then detach the fusing sleeve belt unit [A].
  9. Remove the spring, and then remove the separation plate [A] and supports [B].
How to cancel SC544-02/SC554-02 with a new unit detection fuse

  • To cancel SC544-02/554-02, it is necessary to replace the fusing unit or install an intact new unit detection fuse. If you will cancel these SCs by installing a new unit detection fuse, follow the instruction below.

  • If you are replacing the fusing sleeve unit for PM or any reason other than canceling these SCs, you can discard the fuse that is packed with the new heating sleeve unit.

 

  1. There is a new unit detection fuse packed with the new fusing sleeve belt unit.
  2. Connect the new unit detection fuse to the connector [A], and place the fuse in the empty space [B].

  3. Execute SP5-810-002 [SC Reset: Hard High Temp. Detection].
  4. Execute SP3-701-116 [Manual New Unit Set: #Fusing Belt].