SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC551-01 | A | Thermopile (Edge) Disconnection |
In Machine Condition A, after turning the fusing lamp on, the thermopile (edge) (TH2) has detected the temperature of -50°C or below continuously for 0.1 second. Machine Condition A refers to any of the following conditions:
| ||
| ||
| ||
SC551-02 | A | Non-contact Thermistor (Edge) Disconnection |
In Machine Condition A, after turning the fusing lamp on, the non-contact thermistor (edge) (S47) has detected the temperature of 36°C or higher continuously for 1 second. Machine Condition A refers to any of the following conditions:
| ||
| ||
| ||
SC551-03 | A | Non-contact Thermistor (Edge) Short-circuit |
In Machine Condition A, after turning the fusing lamp on, the non-contact thermistor (edge) (S47) has detected the AD value of 8 or below continuously for 1 second. Machine Condition A refers to any of the following conditions:
| ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC552-02 | A | Thermopile (Edge) Does Not Reload |
In Machine Condition B, after turning the fusing lamp (edge) on, the thermopile (edge) (TH2) has failed to reach 65°C in 14 seconds. Machine Condition B refers to any of the following conditions:
| ||
SC552-03 | A | Thermopile (Edge) Does Not Reload |
In Machine Condition B, after turning the fusing lamp (edge) on, the thermopile (edge) (TH2) has failed to reach the "permissible temperature for reloading" in 28 seconds. Machine Condition B refers to any of the following conditions:
| ||
SC552-05 | D | Thermopile (Edge) Does Not Reload (Low Power) |
The detection criteria is the same as that for SC552-02. | ||
SC552-06 | D | Thermopile (Edge) Does Not Reload (Low Power) |
The detection criteria is the same as that for SC552-03. | ||
|
|
|
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC553-00 | A | Thermopile (Edge) High Temperature Detection (software) |
The thermopile (edge) (TH2) has detected the temperature of 240°C or higher continuously for 1 second. | ||
| ||
If the problem cannot be solved after performing the above steps, replace the fusing unit. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC554-01 | A | Thermopile (Edge) high temperature detection (hardware) |
In the event of an error | ||
| ||
If the problem cannot be solved after performing the above steps, replace the fusing unit. |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC554-02 | A | Non-contact Thermistor (Edge) high temperature detection (hardware) |
In the event of an error | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC555-01 | A | Fusing Edge Lamp Continuously Heat |
SC555-05 | D | Fusing Edge Lamp Continuously Heat (Low Power) |
|
| After waiting for full power for more than 5 sec continuously.
|
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC557-00 | C | Zero Cross Frequency Exceeded |
In the event of an error | ||
Frequency instability of mains power supply /Noise | ||
- |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC558-01 | C | Low Input Voltage |
Input voltage below the specification is detected on the mains power supply | ||
Low input of mains power supply | ||
- |
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC559-00 | A | Fusing Jam Detected for 3 Times Consecutively |
Fusing jam (does not reach fusing exit sensor (S27)) is detected for 3 times consecutively.
Displays the SC559-00 at the time of integrating the counter each time fusing jam occurs, became fusing jam counter value = 3. The counter value is retained without fusing jam also reset by OFF/ON the power supply.
And enables ON / OFF is this SC, the default is set to OFF, then ON at the time of customer requirements. SP1-142-001 0: OFF (default), 1: ON (Set at the time of customer requirements)
| ||
|
| Fusing unit paper jam |
|