The up time for each power state of the machine can be checked with SP8-961 (Electricity Status). It is also output on the SMC sheet.
SP | Name | Description |
---|---|---|
SP8-961-001 | Ctrl Standby Time | Cumulative time of Engine OFF mode, Quiet mode, and Standby mode |
SP8-961-002 | STR Time | Cumulative time of STR mode |
SP8-961-003 | Main Power Off Time | Cumulative time of state in which the power plug is connected to the outlet but the main power is off |
SP8-961-004 | Reading and Printing Time | Cumulative time of state in which both the plotter engine and scanner engine are running or warming up |
SP8-961-005 | Printing Time | Cumulative time of the state in which the plotter engine is running |
SP8-961-006 | Reading Time | Cumulative time of the state in which the scanner engine is running |
SP8-961-007 | Eng Waiting Time | Cumulative time of state in which the power state of the engine is Standby state |
SP8-961-008 | Low Power State Time | Not used for this machine |
SP8-961-009 | Quiet State Time | Cumulative time of the state in which the power state of the engine is Quiet state |
SP8-961-010 | Heater Off State Time | Cumulative time of the state in which the power state of the engine is Fusing OFF state |
SP8-961-011 | LCD on Time | Cumulative time of the state in which the backlight of the LCD is on. |