- SP7-621-001 (PM Counter Display: Paper)
Displays the number of sheets printed for each current maintenance unit.
When a unit is replaced, the machine automatically detects that the new unit is installed.
Then, the current PM counter value is automatically moved to the PM Counter – Previous (SP7-906-1 to 10) and is reset to "0". - SP7-853 (Replace Counter)
Displays the number of times each PM part has been replaced. - SP7-908 (Previous Unit Counter: Pages (%))
Displays the PM counter of the previous PM Part which was replaced last time. - SP7-950 (Unit Replacement Date)
Displays the replacement date of each PM unit. - SP5-990
Prints the configuration sheets of the system and user settings: SMC.