• SP7-621-001 (PM Counter Display: Paper)
    Displays the number of sheets printed for each current maintenance unit.
    When a unit is replaced, the machine automatically detects that the new unit is installed.
    Then, the current PM counter value is automatically moved to the PM Counter – Previous (SP7-906-1 to 10) and is reset to "0".
  • SP7-853 (Replace Counter)
    Displays the number of times each PM part has been replaced.
  • SP7-908 (Previous Unit Counter: Pages (%))
    Displays the PM counter of the previous PM Part which was replaced last time.
  • SP7-950 (Unit Replacement Date)
    Displays the replacement date of each PM unit.
  • SP5-990
    Prints the configuration sheets of the system and user settings: SMC.
    Make sure to shut down and reboot the machine once before printing the SMC. Otherwise, the latest settings may not be collected when the SMC is printed.