When reinstalling the paper transfer roller, do not install the wrong type of roller.
[A]: Standard roller
[B]: Imageable Area Extension Unit Type M19
When attaching the paper transfer roller, make sure that the roller is set in the correct position while referring to the three points described below.
- If the paper transfer roller is set incorrectly, the following problems may occur.
- Damage to the image transfer belt
- Roller detachment when opening and closing the paper transfer roller unit to remove a paper jam
- The paper transfer roller unit does not open
- Check that the tab [A] on the roller holder is under the guide plate [B].
- Check that the pin [A] on either end of the paper transfer roller is inserted correctly.
- Check that the spring [A] at either end of the paper transfer roller unit is in the correct position at each end.