Lookup Table
Covers-Added proximity sensor left cover

Airflow control

Dust filter – maintenance interval
300K400K

Airflow control

Others
-
  • Removed Helmholtz system
  • Removed PSU exhaust fan
Item
MP C2004/C2504/C3004/C3504/C4504/C5504/C6004
(Previous Model)
IM C2000/C2500/C3000/C3500/C4500/C5500/C6000
Changes
  • Proximity Sensor Left Cover
    A proximity sensor left cover [A] has been added to the proximity sensor cover.

    On the previous model, it was necessary to remove the proximity sensor cover when installing the bridge unit and other internal finisher options; but on this model, it is possible to install such options by removing only the proximity sensor left cover.



  • Exhaust Filter
    The filters’ position and shape have been changed. On the previous model [A], it was not possible to remove and attach the exhaust filter when the finisher was attached; but on this model [B], it can be done.

  • PSU Exhaust Fan
    The PSU exhaust fan [A], located next to the exhaust filter on the previous model, has been removed. (Same as Met-P2)

    Even without the fan, the PSU temperature stays within the required range, so the print quality is not affected.


  • Helmholtz System
    The Helmholtz system [A] has been removed.

  • Scanner Support
    The location of the scanner support has been changed slightly.

    [A]: On the left side, previous model; [B]: In the center, current model.