Lookup Table
| Covers | - | Added proximity sensor left cover |
Airflow control Dust filter – maintenance interval | 300K | 400K |
Airflow control Others | - |
|
Item | MP C2004/C2504/C3004/C3504/C4504/C5504/C6004 (Previous Model) | IM C2000/C2500/C3000/C3500/C4500/C5500/C6000 |
|---|
Changes
Proximity Sensor Left Cover
A proximity sensor left cover [A] has been added to the proximity sensor cover.On the previous model, it was necessary to remove the proximity sensor cover when installing the bridge unit and other internal finisher options; but on this model, it is possible to install such options by removing only the proximity sensor left cover.

- Exhaust Filter
The filters’ position and shape have been changed. On the previous model [A], it was not possible to remove and attach the exhaust filter when the finisher was attached; but on this model [B], it can be done.
PSU Exhaust Fan
The PSU exhaust fan [A], located next to the exhaust filter on the previous model, has been removed. (Same as Met-P2)Even without the fan, the PSU temperature stays within the required range, so the print quality is not affected.

- Helmholtz System
The Helmholtz system [A] has been removed.
- Scanner Support
The location of the scanner support has been changed slightly.[A]: On the left side, previous model; [B]: In the center, current model.