Procedure 1: Operation check for the lower side of the shield detection feeler
- Place the fusing unit on a flat place and tilt it towards the drawer connector [A].
- Move the shield drive gear with your hands to put the upper surface of the feeler [A] in a horizontal position.
- It is necessary to move the gear to move the feeler.
- Moving the feeler directly will affect smooth operation, so be sure to move the gear.
- Keep your fingers off the shield drive gear.
- Make sure that the shield detection feeler [A] moves down to the lowest point by its own weight.
- The feeler moves smoothly: OK
- The feeler does not move / stops during moving / moves slowly: NG
Procedure 2: Operation check for the upper side of the shield detection feeler
- Place the fusing unit on a flat place with the drawer connector [A] turned up and the handle [B] touching a flat surface.
- Move the shield drive gear with your hands to put the upper surface of the feeler [A] in a vertical position.
- It is necessary to move the gear to move the feeler.
- Moving the feeler directly will affect smooth operation, so be sure to move the gear.
- Keep your fingers off of the shield drive gear.
- Make sure that the shield detection feeler [A] moves up to the highest point by its own weight.
- The feeler moves smoothly: OK
- The feeler does not move / stops during moving / moves slowly: NG
Results
- Both Procedure 1 and 2 are OK: No problem.
- Either Procedure 1 or 2 is NG: The mechanism is blocked.
- The shield detection feeler never moves while moving the shield drive gear by hands or fingers: Locked.