Smart Operation Panel communicates with the controller via the USB cable [Fig.1-A] and harness [Fig.1-B].

SC672 is displayed upon detecting that communication failure between Smart Operation Panel and the controller.

  • If SC672 occurs when Smart Operation Panel is off [Fig.2], handle the problem according to this procedure, not those for the SC brunch number.

Fig. 3: Smart Operation Panel block diagram

[A]: USB cable

[B]: Harness

[C]: DIMM

[D]: LED

[E]: Fuse

SCCause

SC672-00

Communication error between operation panel and controller after machine is powered on.

SC672-10

Communication error (receive) between operation panel and controller after machine is powered on.

SC672-11

Communication error (send) between operation panel and controller after machine is powered on.

SC672-12

Communication error between operation panel and controller after normal start-up.

SC672-13

If communication error between the operation panel and controller is detected due to a cause other than those stated above (-00, -10, -11, and -12).

SC672-20

Harness connection error on the operation panel.

SC672-21

Controller board error.

SC672-99

Unexpected shutdown of the operation panel's software (OCS).