• SP1-903-003, and 004 (Amplitude Setting)
    Displays amplitude value of BIT1 control.
  • SP2-111-001 (Forced Line Position Adj.: Mode a)
    Executes MUSIC mode a ( fine-tune x 2)
  • SP2-111-002 (Forced Line Position Adj.: Mode b)
    Executes MUSIC mode b ( fine-tune x 1)
  • SP2-111-003 (Forced Line Position Adj.: Mode c)
    Executes MUSIC mode c (rough-tune x 1)
  • SP2-111-004 (Forced Line Position Adj.: Mode d)
    Executes MUSIC mode d (rough-tune, fine-tune, then contact MUSIC)
  • SP2-194-007 (MUSIC Execution Result: Execution Result)
    Displays the execution results of MUSIC.
    0: Completed successfully, 1: Failed
  • SP2-194-010,-011, and -012 (MUSIC Execution Result:Error Result: C, M, Y)
    Displays the details of MUSIC results for each color.
  • SP3-011-001 (Manual ProCon :Exe: Normal ProCon)
    Executes Pro-Con.
  • SP3-011-002 (Manual ProCon :Exe: Density Adjustment)
    Executes toner density adjusting Pro-Con.
  • SP3-011-003 (Manual ProCon :Exe: ACC RunTime ProCon)
    Executes pre-ACC Pro-Con.
  • SP3-011-004 (Manual ProCon :Exe: Full MUSIC)
    Executes Pro-Con / full MUSIC.
  • SP3-011-005 (Manual ProCon :Exe: Normal MUSIC)
    Executes Pro-Con / normal MUSIC.
  • SP3-012-001 to 010 (ProCon OK?: Front)
    Displays the history for past 10 times of ProCon results code detected by the front TM/ID sensor. The code is 2 digits per color from left, in the order of YMCK.
  • SP3-012-011 to 020 (ProCon OK?: Center)
    Displays the history for past 10 times of ProCon results code detected by the center TM/ID sensor. The code is 2 digits per color from left, in the order of YMCK.
  • SP3-012-021 to 030 (ProCon OK?: Rear)
    Displays the history for past 10 times of ProCon results code detected by the rear TM/ID sensor. The code is 2 digits per color from left, in the order of YMCK.
  • SP3-400-001 to 004 (Toner Supply Type: Select; Bk, C, M, Y)
    Selects the toner supply mode.
    0: FIXED, 2: PID, 4: DANK
  • SP3-530-001 to 008 (PowerON ProCon :Set)
    Specifies the non-use time setting, temperature, relative humidity, absolute humidity or page interval as the threshold of process control execution determination at power on.
  • SP3-531-001 to 004 (Non-useTime Procon :Set)
    Specifies the non-use time setting, temperature, relative humidity, absolute humidity or page interval as the threshold of process control execution determination for during the standby mode.
  • SP3-533-001 (Interrupt ProCon :Set: Interval:Set:BW)
    Specifies the number of sheets interval for Interrupt Pro-Con (BW).
  • SP3-533-002 (Interrupt ProCon :Set: Interval:Disp:BW)
    Displays the number of sheets interval for Interrupt Pro-Con (BW).
  • SP3-533-003 (Interrupt ProCon :Set: Corr(Short):BW)
    Specifies the correcting coefficient (Short) of number of sheets interval for Interrupt Pro-Con (BW).
  • SP3-533-004 (Interrupt ProCon :Set: Corr(Mid):BW)
    Specifies the correcting coefficient (Mid) of number of sheets interval for Interrupt Pro-Con (BW).
  • SP3-533-011 (Interrupt ProCon :Set: Interval:Set:FC)
    Specifies the number of sheets interval for Interrupt Pro-Con (FC).
  • SP3-533-012 (Interrupt ProCon :Set: nterval:Disp:FC)
    Displays the number of sheets interval for Interrupt Pro-Con (FC).
  • SP3-533-013 (Interrupt ProCon :Set: Corr(Short):FC)
    Specifies the correcting coefficient (Short) of number of sheets interval for Interrupt Pro-Con (FC).
  • SP3-533-014 (Interrupt ProCon :Set: Corr(Mid):FC)
    Specifies the correcting coefficient (Mid) of number of sheets interval for Interrupt Pro-Con (FC).
  • SP3-534-001 (JobEnd ProCon :Set: Interval:Set:BW)
    Specifies the number of sheets interval for Job end Pro-Con (BW).
  • SP3-534-002 (JobEnd ProCon :Set: Interval:Disp:BW)
    Displays the number of sheets interval for Job end Pro-Con (BW).
  • SP3-534-003 (JobEnd ProCon :Set: Corr(Short):BW)
    Specifies the correcting coefficient (Short) of number of sheets interval for Job end Pro-Con (BW).
  • SP3-534-004 (JobEnd ProCon :Set: Corr(Mid):BW)
    Specifies the correcting coefficient (Mid) of number of sheets interval for Job end Pro-Con (BW).
  • SP3-534-011 (JobEnd ProCon :Set: Interval:Set:FC)
    Specifies the number of sheets interval for Job end Pro-Con (FC).
  • SP3-534-012 (JobEnd ProCon :Set: Interval:Disp:FC)
    Displays the number of sheets interval for Job end Pro-Con (FC).
  • SP3-534-013 (JobEnd ProCon :Set: Corr(Short):FC)
    Specifies the correcting coefficient (Short) of number of sheets interval for Job end Pro-Con (FC).
  • SP3-534-014 (JobEnd ProCon :Set: Corr(Mid):FC)
    Specifies the correcting coefficient (Mid) of number of sheets interval for Job end Pro-Con (BW).
  • SP3-539-001 (Dev Agitating Time :Set: Time)
    Specifies the developer agitating time.
  • SP3-600-002 (Select ProCon: LD Control)
    Specifies the LD control mode.
    0:OFF, 1:ON
  • SP3-600-030 (Select ProCon: IBACC:ON/OFF)
    Specifies ON/OFF of IBACC.
    0: OFF, 1: ON