If necessary, adjust the registration for the paper feed tray.

  • SP1-002-002 (Side-to-Side Registration Paper Tray 1)
  • SP1-002-003 (Side-to-Side Registration Paper Tray 2)


SP descriptions

  • SP1-002 (Side-to-Side Registration)

Adjusts the side-to-side registration by changing the laser main scan start position for each mode and tray.

Increasing a value: The image is moved towards the rear edge of the paper.

Decreasing a value: The image is moved towards the front edge of the paper.