• Insert the plug firmly in the outlet.
  • Do not use an outlet extension plug or cord.

Input Voltage Level

Destination

Power supply voltage

Rated current consumption

Permissible voltage fluctuation

NA

120 to 127V

12A or more

Image quality guaranteed: 108V (120V-10%) to 138V (127V+8.66%)

Machine operation guaranteed: 102V (120V-15%) to 138V (127V+8.66%)

EU

220 to 240V

10A

Image quality guaranteed: 198V (220V-10%) to 264V (240V+10%)

Machine operation guaranteed: 187V (220-15%) to 276V (240V+15%)

AP

CHN