- Check and perform the image position adjustment before you do the following scanner adjustments. (Refer to Image Position Adjustment)
- Use a C4 test chart to do the following adjustments.
Scanner leading edge and side-to-side registration
- Put the test chart on the exposure glass. Then make a copy from one of the feed stations.
A: Leading Edge RegistrationB: Side-to-side Registration
Check the leading edge and side-to-side registration.
A: 4.2 ± 2mm
B: 2.0 ± 1mmAdjust the following SP modes if necessary.
Name SP mode
Leading edge registration (Home Position Adj Value)
SP4-803-001
Side-to-Side Registration (Main Scan Reg)
SP4-011-001
Scanner magnification
- Put the test chart on the exposure glass. Then make a copy from one of the feed stations.
A: Sub-scan magnification
- Check the magnification ratio.
Standard:- Normal mode for main-scan: ±0.55% or less
- Normal mode for sub-scan: ±1.00% or less
- Reduction mode for main-scan: ±1.00% or less
- Enlargement mode for main-scan: ±1.00% or less
- Adjust with SP4-008 if necessary.
Scanner shading correction
- Turn the power OFF and then ON.
The shading correction is executed automatically when the machine is rebooted.