SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC541-01 | A | Thermopile (Center) Disconnection |
In Machine Condition A, after turning the fusing lamp on, the thermopile (center) (TH1) has detected the temperature of -50°C or below continuously for 0.1 second Machine Condition A refers to any of the following conditions:
| ||
| ||
| ||
SC541-02 | A | Non-contact Thermistor (Center) Disconnection |
In Machine Condition A, after turning the fusing lamp on, the non-contact thermistor (center) (S46) has detected the temperature of 36°C or higher continuously for 1 second. Machine Condition A refers to any of the following conditions:
| ||
| ||
| ||
SC541-03 | A | Non-contact Thermistor (Center) short-circuit |
In Machine Condition A, after turning the fusing lamp on, the non-contact thermistor (center) (S46) has detected the AD value of 8 or below continuously for 1 second. Machine Condition A refers to any of the following conditions:
| ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC542-02 | A | Thermopile (Center) does not reload |
In Machine Condition B, after turning the fusing lamp (center) on, the thermopile (center) (TH1) has failed to reach 65°C in 10 seconds. Machine Condition B refers to any of the following conditions:
| ||
SC542-03 | A | Thermopile (Center) does not reload |
In Machine Condition B, after turning the fusing lamp (center) on, the thermopile (center) (TH1) has failed to reach the "permissible temperature for reloading" in 35 seconds. Machine Condition B refers to any of the following conditions:
| ||
SC542-05 | D | Thermopile (Center) does not reload (Low Power) |
In Machine Condition B, after turning the fusing lamp (center) on, the thermopile (center) (TH1) has failed to reach 65°C in 10 seconds. Machine Condition B refers to any of the following conditions:
| ||
SC542-06 | D | Thermopile (Center) does not reload (Low Power) |
In Machine Condition B, after turning the fusing lamp (center) on, the thermopile (center) (TH1) has failed to reach the "permissible temperature for reloading" in 35 seconds. Machine Condition B refers to any of the following conditions:
| ||
|
|
|
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC543-00 | A | Thermopile (Center) high temperature detection (software) |
The thermopile (center) (TH1) has detected the temperature of 240°C or higher continuously for 1 second. | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC544-01 | A | Thermopile (Center) high temperature detection (hardware) |
In the event of an error | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC544-02 | A | Non-contact Thermistor (Center) high temperature detection (hardware) |
In the event of an error | ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC545-01 | A | Fusing Central Lamp Continuously Heat |
SC545-05 | D | Fusing Central Lamp Continuously Heat (Low Power) |
After waiting for full power for more than 5 sec continuously.
Continuously heating rate set point (maximum heating rate)
After reload (after fusing lamp extinguished, after rotation complete) below the standby temperature (target temperature), measurement starts after a fusing lamp heat-up request is issued.
Rotation started due to a print signal during measurement or other.
| ||
| ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC547-01 | D | Zero cross error (relay-contact soldering) |
Zero-cross signal is detected while the fusing relay is OFF. | ||
| ||
| ||
SC547-02 | D | Zero cross error (relay contact error) |
Zero-cross signal is not detected while the fusing relay is ON. | ||
| ||
| ||
SC547-03 | D | Zero cross error (low-frequency error) |
Mains power supply frequency is determined to be 44 Hz or lower. | ||
Frequency instability of mains power supply | ||
|
SC No. | Type | Error Name/Error Condition/Major Cause/Solution |
SC549-02 | D | Fusing Shield Operation Error |
During HP detection operation, shield sensors detect "High" for 2 sec. continuously. | ||
SC549-03 | D | Fusing Shield Operation Error |
During shield basic operation, shield motor does not stop even if 2 sec. elapsed from rotation start. | ||
SC549-04 | D | Fusing Shield Operation Error |
During HP detection operation, HP detection fails 5 times consecutively. | ||
SC549-05 | C | Fusing Shield Operation Error |
- | ||
| ||
Also, refer to When SC549 (Shield Operation Error Detection) is Displayed |