1. Turn on the main power switch, and then go into the SP mode.
  2. Run SP3-011-004 (Manual Procon: Exe Full MUSIC).

  3. Check the result code with SP3-012-001 to 030.
Related SP
  • SP3-011-004 (Manual ProCon :Exe: Full MUSIC)
    Executes Process Control and full MUSIC.
  • SP3-012-001 to 010 (ProCon OK?: Front)
    Displays the past 10 Process Control result codes detected by the front TM/ID sensor. The code is 2 digits per color from the left, in the order of YMCK.
  • SP3-012-011 to 020 (ProCon OK?: Center)
    Displays the past 10 Process Control result codes detected by the center TM/ID sensor. The code is 2 digits per color from the left, in the order of YMCK.
  • SP3-012-021 to 030 (ProCon OK?: Rear)
    Displays the past 10 Process Control result codes detected by the rear TM/ID sensor. The code is 2 digits per color from left, in the order of YMCK.
ProCon results code

Category

Code

Result name

Description

00 and larger

00

Not executed

Factory default setting (SP default)

10 and larger

Result (Normal)

11

Succeeded

-

40 and larger

ID Sensor

 

 

 

41

ID sensor output error (Max)

Vt > Max

42

ID sensor output error (Min)

Vt < Min

43

ID Sensor error (Max)

Development gamma is in target, but Vt value is less than upper limit.

44

ID Sensor error (Min)

Development gamma is in target, but Vt value is less than lower limit.

45 and larger

ID Pattern detection

45

ID Pattern extract error

Cannot detect ID Pattern

50

Vmin_Bk/K2 error(Max)

K:Vmin_Bk / CMY:K2>Max

51

Vmin_Bk/K2 error(Min)

K:Vmin_Bk / CMY:K2<Min

52

K5 error (Max)

K5>Max

53

K5 error (Min)

K5<Min

54

K5 calculated approximate point error

K5 calculated approximate point <Min

55

Development gamma error (Max)

Development gamma >Max

56

Development gamma error (Min)

Development gamma <Min

57

Start developing voltage: Vk error(Max)

Start developing voltage: Vk>Max

58

Start developing voltage: Vk error(Min)

Start developing voltage: Vk<Min

59

Not enough valid data

Adhesion amount data for development gamma calculation point is under 2

60 and larger

Potential adjustment

61

LD won’t light

P pattern is not written.

62

Residual potential: Vr error

Vr>Max

63

Electrified potential: Vd adjust error

Vd cannot be adjusted in the target range.

64

Exposure potential: Vpl adjust error

Vpl cannot be adjusted in the target range

90 and larger

Result(End)

90

Potential not adjusted

Potential control method is set as [0:FIX]

99

Stopped

Stopped by door open, power off, error.

(Set when to execute.)

  • Execution result example (In order of YMCK from left)
  • Factory default (SP default): [00,00,00,00]
  • Starting adjust: [99,99,99,99]
  • Fail Vsg adjust(Y): [21,99,99,99]
  • Error of Development gamma Max(C): [99,99,55,99]
  • Succeeded: [11,11,11,11]